OPL pneumatic stoppersOPL pneumatic stoppers

Standard inflatable pipe plug - OPL

The standard inflatable pipe plug (OPL) is designed to temporarily or permanently plug pipes, sewers or gutters. Flexible and light, it is effective for a fast, tight and reliable sealing of the pipe.

Many sizes are available to cover pipes from 30 to 2000 mm in diameter. Thanks to these various diameters, this plugging balloon can be used in many fields : sewage networks, rainwater and wastewater with the NR range, as well as hydrocarbons and/or chemicals with the NBR range.

Moreover, the standard inflatable pipe plug is available in standard or by-pass versions. Thanks to this adaptability, it is possible to safely carry out an application such as:

  • Pipe repairs,
  • Pipeline maintenance,
  • Flow deviations,
  • Air or water tightness test, according to the NF-EN1610 standard,
  • And hydraulic testing.

Designed from elastomer, the range of inflatable plugs meets high internal safety criteria (see also the OPAP and OFR emergency pipe plug). Pronal is aware of the risks incurred by the users of the inflatable plugs and puts the priority on the performance of these products. Thus, the OPL range is designed to resist a minimum bursting safety coefficient of 3. In addition, the rubber used offers very good performance against abrasion and slippage. 

Choosing this range of OPL inflatable pipe stoppers means working with a high-performance and reliable product that will last over time!

Avantages

Reliability

  • High pressure and back-pressure
  • Total water and air tightness
  • High quality materials

Safety

  • Excellent back-pressure resistance
  • Safety coefficient of at least 3
  • Highly scratch-resistant

Installation

  • Easy installation

Informations détaillées

  • Material :
    • NR for sewage systems, rainwater and wastewater.
    • NBR for hydrocarbons and chemicals.
  • Technique: vulcanisation
  • Length: 150 > 2750 mm
  • Max. diameter: 60 > 2000 mm
  • Inflation: by air
  • Temperature resistance: -20 to +60°C (please contact us for any use outside of this temperature range)
  • Inflation pressure: max. 3 bar
  • Back-pressure: download the OPL product sheet below
  • Optional materials: thermal protection

For all OPLT information and back-pressures (with bypass), refer to the tables which are found on the product sheet, downloadable below.

Informations techniques

Ref. Stopper Min. Ø stopper (mm) Max. Ø stopper (mm) Ø (mm) Length (mm) Inflation pressure Weight (kg) Hoisting ring
OPL 30/60 30 60 29 150 2.5 0.2 NA
OPL 45/80 45 80 43 150 2.5 0.3 NA
OPL 50/100 50 100 45 110 2.5 0.3 NA
OPL 65/125 65 125 63 250 2.5 0.4 NA
OPLS 75/150 75 150 70 195 2.5 0.5 NA
OPL 75/150 75 150 70 350 2.5 0.8 NA
OPLS 100/200 100 200 90 250 2.5 0.8 NA
OPL 100/200 100 200 86 350 2.5 1.3 NA
OPL 100/150 100 150 90 125 2.5 0.6 NA
OPL 100/250 100 250 86 600 2.5 2.2 NA
OPL 125/200 125 200 110 152 2.5 0.7 NA
OPL 150/250 150 250 145 255 2.5 2 1xM8
OPL 150/300 150 300 145 255 2.5 2.6 1xM8
OPL 200/400 200 400 190 555 2.5 5.5 2xM10
OPL 300/500 300 500 170 725 2.5 5.5 1xM8
OPL 300/600 300 600 288 715 2.5 12 2xM10
OPL 300/800 300 800 275 1200 2.5 12 2xM12
OPL 400/800 400 800 370 1030 2.5 22 2xM12
OPL 500/1000 500 1000 472 1140 2.5 32.5 2xM12
OPL 500/1400 500 1400 490 2200 1.5 55 2xM12
OPL 600/1200 600 1200 570 1400 1.5 49 2xM16
OPL 600/1500 600 1500 570 2180 1.5 65 3xM16
OPL 800/1600 800 1600 770 2000 1.5 90 3xM16
OPL 800/2000 800 2000 760 2750 1.5 125 4xM16

Vous ne trouvez pas vos dimensions

Notre bureau d'études composé des meilleurs chefs de projets et de desssinateurs sauront imaginer et créer un produit sur-mesure spécialement pour vous et votre projet unique.

sur mesure

Composition / Conseils

Pre-installation tips
Inspect the pipeline and remove any rough elements (stones, deposits …). Do not inflate the stopper when it is outside the pipeline. Never place a foreign object between the walls of the pipe and the stopper.
Maintenance tips
Carefully check all the external surfaces to ensure that there are no obvious deformations (folds, bulges, or cuts). Clean the product (using slightly soapy water but not a detergent) and dry completely.
Storage advice
Store in its original case away from light, damp, and temperature variations.

Normes / réglementations

Guaranty
1 year against all manufacturing defects

Téléchargement

Fiches techniques / guides métier
  • This field is for validation purposes and should be left unchanged.

Accessoires

"Simplified" control unit
Flexible inflation hose, 5 or 10 m
Geka and quick couplers
Safety cable
Pressure reducer
COOKIES
Nous utilisons des cookies pour vous permettre de visiter et d'utiliser notre site. Certains cookies sont nécessaires à son fonctionnement et ne peuvent pas être désactivés. D'autres cookies de collecte de données nous aident à améliorer la pertinence de notre contenu. Ces cookies ne sont activés que si vous consentez à leur utilisation en cliquant ci-dessous.
Accepter
Ces cookies permettent de suivre le parcours utilisateur, le passage sur un site pour une évaluation et une stratégie marketing.
Ces cookies permettent d'obtenir des statistiques de fréquentation anonymes du site afin d'optimiser son ergonomie, sa navigation et ses contenus.
Tout refuser